WHAT A GAUGE NUMBER MEANS IN EACH METAL

Sheet Metal Gauge vs Thickness, and What to Write on Your Order

The Same Gauge Number Is a Different Thickness in Each Metal

Name the metal and write the millimetres beside the gauge number whenever a supplier could read it two ways.

Confusion between sheet metal gauge and thickness trips up many orders. A gauge number names a thickness, and that thickness changes with the metal. Sixteen gauge mild steel is about 1.52 mm, galvanized about 1.61 mm, and aluminum about 1.29 mm. A lower number means thicker sheet. This guide gives the millimetres for each gauge and metal and explains why they differ. It also shows what to write so every supplier prices the same sheet.

A Sheet Metal Gauge Chart in Millimetres for Four Metals

Find the number on your order, then read across to the metal.

GaugeMild steel (mm)Galvanized (mm)Stainless (mm)Aluminum (mm)
103.423.513.572.59
122.662.752.782.05
141.901.991.981.63
161.521.611.591.29
181.211.311.271.02
200.911.010.950.81
220.760.850.790.64
240.610.700.640.51
260.460.550.480.40
280.380.470.400.32
300.300.400.320.25

Stainless tables differ between sources, and this column uses the one based on inch fractions, where 16 gauge is 1/16 in. Other charts list 16 gauge stainless at 1.52 mm, and that gap is one more reason to write the millimetres on a stainless order.

Sixteen gauge, four metals, drawn to scale

Each bar is the sheet's edge, magnified 100 times

1.52 mm 1.61 mm 1.59 mm 1.29 mm Mild steel Galvanized Stainless Aluminum
  • zinc coating, counted in the galvanized figure

Why 16 Gauge Means Four Different Thicknesses in Four Metals

Each metal got its numbers from a different system, long before anyone ordered in millimetres. That history explains every gap in the table.

The steel numbers began as a set weight per square foot. Sixteen gauge steel weighs about 12.2 kg per square metre, and its thickness is worked back from that weight. This steel table, the Manufacturers' Standard Gauge or MSG, is the one most Canadian steel charts use.

Each galvanized figure is the steel one plus about 0.09 mm, an allowance for a heavy zinc coat on both faces. If you measure galvanized sheet, you're measuring the steel and its coating together.

Aluminum follows the Brown and Sharpe system made for wire. That's why 18 gauge aluminum is about 1.02 mm, and the same number in steel is about 1.21 mm. If you order aluminum, name the thickness.

Different suppliers list stainless steel by different gauge tables, even for the same grade. If a stainless order gives only the gauge, two shops can price two different sheets, and the millimetres prevent that.

The steps between gauges aren't even, either. In mild steel, 10 to 12 gauge drops about 0.76 mm, but 22 to 24 drops only about 0.15 mm.

What the Standards Say About Ordering by Gauge

The standards that govern sheet metal fabrication agree on one point. They want the thickness written as a measurement, and they treat the old numbers as a convenience at best.

Standard or bodyWhat it coversWhat it says about gauge and thickness
ASTM A480Stainless steel sheet and plateThickness is ordered as a decimal or a fraction. It calls gauge an outdated term, and says the number can't be grounds for rejecting sheet
ASTM A924Galvanized and other coated steel sheetThickness is given to 0.01 mm, and it's the steel and the coating together
Canadian Sheet Steel Building InstituteSheet steel used in Canadian constructionThe numbers aren't regulated, and design and ordering need a decimal thickness
CSA S136Design of cold-formed steel in CanadaDesign thickness is the base steel only, and the delivered sheet can be as thin as 95% of it
National Master Specification, metal ductsDuctwork on Canadian public projectsDuct thickness comes from SMACNA's tables for each duct's size and pressure, not from a gauge chart

For ductwork, the thickness comes out of SMACNA's tables for the duct's size and pressure. That's covered in duct pressure class and gauge.

What Thickness Does a Spec Mean When It Gives a Number?

A thickness on a spec answers two questions. Is it the target or the floor, and does it count the zinc?

Nominal thickness

This is the target the mill rolls the sheet to, and CSA S136 calls it the design thickness. Delivered sheet lands a little above or below it. A spec that gives one figure with no other word usually means nominal.

Minimum thickness

This is the floor. CSA S136 lets 22 gauge steel with a 0.76 mm design thickness arrive at 0.72 mm, so 0.72 mm is its floor. If a spec says minimum, every sheet must reach that figure.

Base metal or coated

Base metal thickness leaves out the zinc, and coated thickness includes it. If your spec says "minimum base metal thickness", the coating doesn't count toward it.

Mills can also deliver galvanized sheet a little over or under. Under ASTM A924, sheet 0.58 to 1.09 mm thick and up to 813 mm wide can vary 0.10 mm either way. If a thinner sheet would cause a problem, write a minimum thickness.

Two Canadian Specs Read "24 Gauge Galvanized" Two Ways

Owner specs are the written requirements a building's owner issues with the drawings. Two published Canadian ones use different tables for galvanized, and the comparison below is an illustration, not a job.

Spec or orderTable it reads gauge byWhat 24 gauge comes to
A UBC spec that writes "0.71 mm thick (24 ga), Z275"The galvanized table, which counts the zincAbout 0.70 mm, steel and zinc together
A City of Winnipeg spec that writes "0.76 mm (22 MSG)"The steel table, MSG, which leaves the zinc outAbout 0.61 mm of bare steel, before the zinc
An order that only says "24 gauge galvanized"Whichever table the supplier happens to useEither 0.61 or 0.70 mm, with no way to tell

The two readings sit about 0.09 mm apart, roughly 15%. A mill's tolerance lets each sheet land a little over or under its figure. This gap is different, because every sheet on the order is built to the other figure. Both specs avoid the problem by writing the millimetres beside the gauge.

Gauge Mix-Ups on an Order, and What to Write Instead

Each of these orders can be read as more than one thickness. Adding the metal and the millimetres leaves only one.

What the order saysWhat goes wrongWhat to write instead
"Heavy duty"Every supplier pictures a different thickness"1.52 mm (16 ga) mild steel"
"16 gauge" with no metal namedIt could mean anything from 1.29 to 1.61 mm"16 ga galvanized, 1.61 mm coated"
"16 gauge stainless"Tables list it at 1.52 or 1.59 mm"304 stainless, 1.59 mm (0.0625 in.)"
"16 gauge aluminum"Aluminum suppliers list sheet in decimal inches, such as 0.050 in."Aluminum, 0.050 in. (1.27 mm)", a listed size close to 16 gauge's 1.29 mm
A gauge and a millimetre figure that disagreeNobody knows which one to build toAsk the engineer which governs, then write that one
"Same as the old one"Nobody knows how thick the old part is"Measured 1.2 mm on a clean edge," naming the metal

If you measure an old galvanized part with calipers, the reading includes its zinc. Measure on a clean, flat edge, and say it was coated.

Who Sets the Sheet Thickness on Common Kinds of Work

Most of the time the thickness isn't yours to pick. It comes from a standard or the designer's drawings, and knowing where to look saves a round of questions.

Kind of workWhat sets the thicknessWhere to find it
HVAC ductworkThe engineer, through SMACNA's tablesThe duct construction table or mechanical spec
Grease duct from a cooking hoodNFPA 96, the grease duct standard, at no thinner than No. 16 gauge mild steel or No. 18 stainless. Its own millimetre figures vary by edition, so ask the inspector which appliesThe mechanical drawings and the local inspector
Flashing and roofing sheetThe architect's specThe roofing or sheet metal section of the spec
Stainless counters and food-service tablesThe kitchen designer or the owner's specThe equipment schedule or the drawing
Brackets, covers, and equipment partsThe designer, based on load and stiffnessThe part drawing, or ask us to suggest one

Grease duct thickness is covered in full in grease duct specifications explained. Counter thickness and its effect on price are in what affects the cost of a custom stainless steel countertop.

How Duct Duct Goose Reads the Gauge on Your Order

Every order is read for its metal and thickness before any sheet is cut. When a gauge and a millimetre figure disagree, we ask instead of guessing.

  1. Reading the metal with the gauge. We match each gauge to the right table for its metal, and check any millimetres written beside it.

  2. Checking our ranges. We work mild steel about 0.30 to 1.90 mm, galvanized 0.40 to 1.99 mm, and aluminum 0.25 to 1.63 mm. That's 30 to 14 gauge, and stainless runs 26 to 14 gauge, about 0.48 to 1.98 mm.

  3. Following SMACNA on ductwork. Every duct job follows SMACNA's construction standards, and where the engineer's spec asks for more, we build to the spec.

  4. Asking about anything unclear. If a thickness is missing or unclear, we ask before pricing, or suggest one when you'd like us to.

  5. Checking before release. Each piece is checked against the drawing before it leaves. If a piece is wrong and the mistake was ours, we fix or remake it at no charge.

Outside those ranges, we'll tell you before pricing whether we can take the work on. Our materials and finishes page lists the metals we work, and cutting and bending shows how the sheet becomes a part.

When a Gauge Number Is Enough, and When to Write Millimetres

A gauge on its own works when everyone already reads it the same way. Anywhere that's in doubt, write the millimetres too.

A gauge on its own usually works

  • Ductwork priced from SMACNA's tables
  • Repeat orders where the shop already has your drawing
  • Mild steel, where one table is in common use

Write the millimetres too

  • Any stainless or aluminum order
  • Galvanized sheet on a spec that names base metal thickness
  • Parts that must fit or match an existing one
  • Jobs priced by more than one shop

If a thinner sheet will do the job and the spec allows it, we'll say so before you pay for heavier metal. We'd rather the order get smaller than have you pay for steel the job doesn't need.

Thicker sheet also costs more to buy and bend, and why stainless fabrication costs more shows where that money goes on stainless.

Thickness Checklist Before You Send an Order

Tick these off, and the thickness on every part reads one way. The full list for a quote is in What Duct Duct Goose Needs to Quote Custom Metalwork. More metal choices are in Choosing Materials and Finishes.

0 of 10 ready

Not Sure Which Thickness? Send the Drawing Anyway

A finished drawing with every thickness marked and a sketch that says "about as thick as the old one" are both fine places to start. We'll read the metal and the thickness, ask about anything unclear, and price the sheet you meant.

Standard ductwork and fittings price instantly on WebDuct, the online pricing and ordering portal, with a company account. Stainless, kitchen exhaust, production parts, installs, and other custom work start with a request or a call.

Sign UpCreate your Duct Duct Goose portal account

Loading the sign-up form…

⚠️Disclaimer!

At Duct Duct Goose, we specialize in sheet metal fabrication and stainless steel services for commercial and industrial applications, including HVAC systems, ducts, and custom metalwork. Please note that we do not offer services for automotive-related projects, such as vehicle parts, repairs, or modifications.